Multi-NIC vMotion lets VMware vSphere use more than one network adapter for a single vMotion, so live migrations finish much faster. Here’s how to set it up in vSphere 5.x on a standard vSwitch using two VMkernel port groups with opposite failover order.
Create the First vMotion Port Group
- Log in to the vSphere Client and select the host in the inventory panel.
- Click the Configuration tab and select Networking.
- Click Add Networking, choose VMkernel as the connection type, and click Next.
- Add two or more NICs to a new or existing standard vSwitch. Note: all adapters must be on the same physical network; if they’re split across switches, those switches must be able to talk to each other.
- Name the VMkernel port group (for example,
vMotion-01) and assign a VLAN ID if needed. - Check Use this port group for vMotion and click Next.
- Enter the IP address and subnet mask and click Next.
- Open the vSwitch Properties, select
vMotion-01, and click Edit. - On the NIC Teaming tab, under Failover Order, select Override switch failover order.
- Set the first adapter (for example,
vmnic1) as Active and move the second (for example,vmnic3) to Unused Adapters. Click OK.

Create the Second vMotion Port Group
- In the vSwitch Properties, click Add to create a second VMkernel port group.
- Name it (for example,
vMotion-02) and assign a VLAN ID if needed. Note: both vMotion VMkernel interfaces must have IP addresses on the same subnet. - Check Use this port group for vMotion, click Next, enter the IP address and subnet mask, and click Next.
- Edit
vMotion-02, go to NIC Teaming, and select Override switch failover order. - Set the second adapter (
vmnic3) as Active and move the first (vmnic1) to Unused Adapters. - Select each vMotion port group in turn and confirm their active and unused adapters are the reverse of each other.
Scaling to More NICs
I repeated these steps two more times because I had four NICs. Each one went to its own physical network card, which was also bound to the software iSCSI HBA. After the change, I migrated the same machines back out across both hosts using all the configured NICs.